Permit: T03CM03546

Parcel: 140374010


Addresses:

6197 E STONECHAT DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/28/2003 FRAMING Approved IVRS - Inspection 0000*
10/27/2003 FRAMING Denied IVRS - Inspection 0935*/ 1) STUCCO ABOVE REAR PATIO NOT COMPLETED 2) NOTHING DONE FROM LAST INSPECTION
10/24/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) SEE #1 AND #2 PREVIOUS INSPECTION 2) WILL RE-FEE NEXT FAILURE
10/23/2003 FRAMING Denied IVRS - Inspection 0999*
10/22/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) NOT READY AS PER SUPER
10/21/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) SEE PREVIOUS INSPECTION 2) REFEE IMPOSED, PAY PRIOR TO NEXT INSPECTION
10/20/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) PROVIDE 2 X 6 OR ALTERNATE FIX AT PLUMBING WALL IN LANDING 3" VENT 2) SECURE PLUMBING WASTE LINES 3) POWDER ROOM INCOMPLETE 4) MECH INCOMPLETE
10/16/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) NO TEST ON DWV'S 2) EXHAUST FAN IN LAUNDRY ROOM NOT CONNECTED 3) NAIL PROTECT WATER LINES WITHIN 1 1/2" FROM EDGE OF STUD 4) STOPPED INSPECTION IN KITCHEN. RECALL WHEN READY 5) LATH INSTALLATION NOT COMPLETED