Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T03CM03532
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/30/2004 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
03/23/2004 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) INSTALL CONCRETE STOOP OUTSIDE DOOR 2) SECURE LIQUID-TITE TO WALL 3) NEED LADDER TO ACCESS ROOF 4) INSTALL PROPER CONNECTIONS LIQUID-TITE CONDUIT 5) 20 AMP CIRCUITS REQUIRE #12 WIRE 6) CUT SEWER CLEANOUTS TO GRADE 7) WHAT IS 1/2" COPPER STUBBED OUTSIDE FOR ? 8) ELECTRIC BASE BOARD HEATER NOT INSTALLED PER PLAN 9) INSTALL SMOKE DETECTORS ALL BEDROOMS AND HALL WAY AND NEW DINING ROOM 10) NEED EXHAUST FAN IN EXISTING BATH 11) NEED INSIDE TO INSPECT J-BOX IN ATTIC 12) LABEL CIRCUITS MAIN PANEL 13) WHAT ARE ALL UNUSED BREAKERS FOR IN MAIN PANEL ? 14) COMPLETE GRADING TO SLOPE AWAY FROM HOUSE 15) STOPPED INSPECTION |