Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM03524

Parcel: 117101530


Addresses:

425 N COURT AV


Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T03CM03524

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
04/01/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*/ 1) CONTRACTOR TO SUPPORT HORIZONTAL ABS AS REQUIRED. 2) CORRECTIONS MADE OK. 3) OK TO COVER ALL AREAS.
03/31/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/ PLEASE READ AND COMPLY WITH ALL CORRECTIONS. SEE NOTE#3 FROM 3/26/04
03/26/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/ 1) NOT INSTALLED PER PLAN. SEE PLBG ISOMETRIC AT P-1. 2) HOT AND COLD PEX PIPING MAY NOT BE BUNDLED TOGETHER. 3) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE THRU WYE BRANCH OR EQUIVELENT SWEEP.
03/24/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/ 1) GAS PRESSURE TEST OK 2) NO TEST ON DWV PIPING