Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM03523
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/02/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
12/01/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) REVISIONS ON PORCH AND ENTRY BEAM HAVE BEEN SUBMITTED TO CITY. RECALL WHEN APPROVED REVISIONS ON SITE | |
11/25/2003 | FRAMING | Denied | IVRS - Inspection 0999* 1) ENTRY BEAM SHALL BE 3 1/2 X 9 1/2 GLU LAM. 2) FIRE BLOCK MISSING 2 PLACES. 3) PORCH DBL JOIST, OVERSPAN. |