Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/21/2003 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 11/13/2003 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE DOUBLE TOP PLATES AT WEST WALL 2) PROVIDE DETAIL FOR BEAM TO WALL CONNECTION AT PORCH HIP FROM ARCH. OF RECORD 3) PROVIDE TRUSS AT EXISTING WALL PER PLAN 4) PLAN CALLS FOR TJI'S NOT TRUSSES PROVIDE APPROVED CHANGES ON PLAN STOPPED INSPECTION |