Permit: T03CM03499

Parcel: 117050330


Addresses:

340 E 6TH ST


Inspection Status: Approved

Inspection History: PLUMBING - PROGRESS

Permit Number - T03CM03499

Inspection Description - PLUMBING - PROGRESS

Inspection Status - Approved

Date Description Inspector Results Comments
08/18/2004 PLUMBING - PROGRESS Approved IVRS - Inspection :*
07/08/2004 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*/ 1) CONTRACTOR WISHES TO COVER SINGLE BATH 2) CLOSET FLANGE OK 3) LOOPED COPPER OK 4) ABS INSTALLED OK-OK TO COVER SUBJECT TO WATER TEST
06/25/2004 PLUMBING - PROGRESS Partial Approval IVRS - Inspection :*/ 1) BAR AREA ONLY OK TO COVER. A) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A WYE OR EQUIVELENT (SWEEP). B) HORIZONTAL VENTING BELOW FLOOD RIM TO BE SWEEPS. C) PERM CAP REQUIRED ON UNUSUAL RISER. D) SUPPORT OVERHEAD VENT - SUPPORTS REQUIRED AT END OF BRANCHES, CHANGE OF DIRECTION, CHANGE OF ELEVATION.