Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T03CM03499
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/18/2004 | PLUMBING - PROGRESS | Approved | IVRS - Inspection :* | |
07/08/2004 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :*/ 1) CONTRACTOR WISHES TO COVER SINGLE BATH 2) CLOSET FLANGE OK 3) LOOPED COPPER OK 4) ABS INSTALLED OK-OK TO COVER SUBJECT TO WATER TEST | |
06/25/2004 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :*/ 1) BAR AREA ONLY OK TO COVER. A) HORIZONTAL X HORIZONTAL CHANGE OF DIRECTION TO BE A WYE OR EQUIVELENT (SWEEP). B) HORIZONTAL VENTING BELOW FLOOD RIM TO BE SWEEPS. C) PERM CAP REQUIRED ON UNUSUAL RISER. D) SUPPORT OVERHEAD VENT - SUPPORTS REQUIRED AT END OF BRANCHES, CHANGE OF DIRECTION, CHANGE OF ELEVATION. |