Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/24/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 09/22/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CANCELLED |
| 09/19/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) A35'S AT GABLE 2) NAIL SHEAR PER DETAIL 3) LATERAL BRACE ON N/E NOT CONNECTED AT TOP PLATE 4) NAIL DRAG WALL AT ROOF 5) RENAIL AT SHINERS |