Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM03491

Parcel: 141173220

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM03491

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/04/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/03/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
09/03/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) NAIL OFF ALL ROOF DECK MISSING NAILS 2) NAIL FREEZE BLOCKS TO ROOF 3) TOP OF SHEAR REAR WALL 4) NEED HANGER FOR GLUE LAM WEST SIDE 5) INSTALL ALL LATERAL BRACES POER TRUSS DRAWINGS 6) STUD AT TUB WALL 7) NAIL GARAGE SHEAR TRANSFER TO ROOF DECK
08/29/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
08/28/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) ROOF NOT NAILED YET