Permit: T03CM03488

Parcel: 122162840


Addresses:

1725 N BAXTER DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/10/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
01/13/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
01/06/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PROVIDE H. D.'S PER PLAN 2) DOUBLE HANGERS INCORRECT FOR DOUBLE JOIST 3) PROVIDE BLOCKS AT SHEAR FOR NAILING 4) RE CHECK ROOF NAILING