Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/11/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 09/10/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) OVERSPAN FRONT OF GARAGE 2) SHEAR FRONT OF GARAGE 3) HOLDOWNS NOT NAILED 4) BEAM NOT INSTALLED AT FRONT 5) WIND BRACE NOT NAILED NORTH WEST WALL 6) SHEAR MISSING NORTH WEST CORNER 7) WIND BRACE NOT NAILED WEST WALL. CHECK ALL BRACING 8) STRAP NORTH WEST CORNER 9) SHEAR NOT NAILED 10) POST CAPS MISSING 11) COMPLY WITH DETAIL 413 SD |
| 09/09/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0950*/ 1) WORK IS NOT COMPLETE ENOUGH TO INSPECT |