Inspection History: FRAMING

Date Description Inspector Results Comments
12/22/2003 FRAMING Approved IVRS - Inspection 0000*/ 1) NOTE: ELECTRIC OUTLETS NOT ALLOWED UNDER COUNTER TOP WITH MORE THAN 6" OVERHANG
12/18/2003 FRAMING Denied IVRS - Inspection 0950*/ 1) NOT COMPLETE, NO CHANGE
12/16/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) STUCCO LATH NORTH WALL NOT STAPLED 2) SEAL VAPOR BARRIER 3) PEX MUST BE 6" FROM W/H "B" VENT 4) NAIL PROTECT DRYER DUCT 5) NAIL PROTECT WIRES WITHIN 1 1/4" OF SURFACE 6) NO GAS TEST 7) BEARING STUDS CANNOT BE NOTCHED GREATER THAN 25 PERCENT ( KITCHEN ) 8) CONVENIENCE OUTLETS NOT ALLOWED UNDER COUNTER TOP EXCEEDING MORE THAN 6" 9) LAVITORY TRAP ARM CANNOT EXCEED 1 1/2" OR 42" IN LENGTH 10) DUCTS RESTRICTED MASTER BEDROOM 11) ENTRY MISSING ANCHOR BOLTS 12) FILL GIRDER CLIP WITH NAILS