Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
Permit Number - T03CM03474
Inspection Description - PLUMBING - ROUGH, SOIL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/23/2004 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection 0000* | |
01/22/2004 | PLUMBING - ROUGH, SOIL | Not ready for Inspection | IVRS - Inspection 0000*/ 1) CANCELLED | |
01/21/2004 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection 0999*/ 1) SWEEP FITTING REQUIRED ON VERTICAL TO HORIZONTAL DRAIN 2) MAXIMUM DISTANCE FROM 2" TRAP TO VENT IS 60" 3) 10' WATER TEST REQUIRED 4) CONNECT ALL DRAINAGE TO BE INCLUDED IN TEST |