Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/24/2003 FRAMING Approved IVRS - Inspection 0000*
10/23/2003 FRAMING Partial Approval IVRS - Inspection 0000*
10/22/2003 FRAMING Denied IVRS - Inspection 0999* MESH INCOMPLETE, WORK IN PROGRESS
10/22/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) SMOKE DETECTORS MUST BE A MINIMUM OF 36" AWAY FROM REGISTER 2) IN HALLWAY OSB SITTING ON TOP OF ROMEX AT ATTIC ACCESS FIX 3) OVERSPANS RIGHT SIDE OF MASTER BEDROOM WINDOW 4) NAIL PROTECT PLUMBING AT MASTER BATH FROM BOTH SIDES 5) MISSING ANCHOR BOLTS WITHIN 12" OF CUT AT GARAGE