Permit: T03CM03457

Parcel: 141305540

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM03457

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/27/2003 FRAMING Approved IVRS - Inspection 0000*
10/23/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) COMPLY WITH DETAIL 7 SD3, GABLE TIE BRACE AND 2 X 4 BLOCKING NOT PER PLAN 2) OVER NOTCHED STUD AT SOUTH EAST EXTERIOR WALL, REPLACE 3) OVERSPAN SOUTH EAST WALL 4) REPLACE OVERBORED ICING AND TRIMMER STUDS AT KITCHEN WINDOW 5) #8 PARTIAL FOR PLUMBING WATER LINES WILL NEED TO RE-INSPECT PLUMBING AT KITCHEN
10/22/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) NO WATER IN DWV TEST 2) NOTCH OUT AT DRYER VENT TOP PLATE 3) LARGE CRSS BRACES FOR TRUSSES MAKE A NAILS AT BRACE ENDS IN SHEAR, NOT TOE NAILS 4) DAMAGED STUD EAST WALL LIVING ROOM 5) TIE WALL TO TRUSS LIVING ROOM 6) BANG PLATE REAR HOSE BIB 7) PLATE CUT BUT REAR KITCHEN, SECURE, TOP PLATE BANG P. WATER LINES 8) SECURE AND NAIL CORNER TUB STUD, BANG PLATE WATER LINES ON TOILET SIDE