Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM03457
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/27/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
10/23/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) COMPLY WITH DETAIL 7 SD3, GABLE TIE BRACE AND 2 X 4 BLOCKING NOT PER PLAN 2) OVER NOTCHED STUD AT SOUTH EAST EXTERIOR WALL, REPLACE 3) OVERSPAN SOUTH EAST WALL 4) REPLACE OVERBORED ICING AND TRIMMER STUDS AT KITCHEN WINDOW 5) #8 PARTIAL FOR PLUMBING WATER LINES WILL NEED TO RE-INSPECT PLUMBING AT KITCHEN | |
10/22/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NO WATER IN DWV TEST 2) NOTCH OUT AT DRYER VENT TOP PLATE 3) LARGE CRSS BRACES FOR TRUSSES MAKE A NAILS AT BRACE ENDS IN SHEAR, NOT TOE NAILS 4) DAMAGED STUD EAST WALL LIVING ROOM 5) TIE WALL TO TRUSS LIVING ROOM 6) BANG PLATE REAR HOSE BIB 7) PLATE CUT BUT REAR KITCHEN, SECURE, TOP PLATE BANG P. WATER LINES 8) SECURE AND NAIL CORNER TUB STUD, BANG PLATE WATER LINES ON TOILET SIDE |