Permit: T03CM03437

Parcel: 116036160

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T03CM03437

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/25/2003 FRAMING Approved IVRS - Inspection 0000*
09/24/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) INTERIOR BEARING WALLS REQUIRE ANCHOR BOLTS AT 48" ON CENTER 2) INTERIOR BEARING WALLS REQUIRE H2.5 WILL ALL HOLES FILLER 3) 12/A8A NOT COMPLIED WITH AT SHEAR WALL INTERSECTION 4) REPAIR BROKEN FIRE BLOCKS BATH 5) OVER SPAN BATH
09/19/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) LOAD ROOF
09/18/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) LOAD ROOF 2) OVER BORED, OVER NOTCHED STUDS 3) 12" ON CENTER STRUDS AT INTERIOR WALL 4) TOO MANY ITEMS TO LIST, REVIEW PLANS AND CODE REQUIREMENTS PRIOR TO RECALL
09/16/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) OVER BORED STUDS 2) 12" ON CENTER INTERIOR BEARING 3) FIRESTOP DROPS 4) NAIL PLATE 220 V 5) NO TEST, NAIL PLATES 6) BLOCKING NOT COMPLETED 7) SUPPORT 8) NOTE: REVIEW AND INSTALL ALL DETAILS PER PLAN
09/15/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*