Permit: T03CM03408

Parcel: 13342001C

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
12/15/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
12/02/2004 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*/TEST ON WASTE VENTS & WATER OK. WILL NEED TEST ON TUBS ALSO NEED LETTER OF APPROVAL FROM ARCHITECT ON USE OF CPVC INSIDE BLDG. NOT IN SPEC AT THIS TIME
11/24/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :/1)SUPPORT ALL PIPING AT CORRECT INTERVALS WITH APPROVED METHODS (4' MAX ON HORIZONTAL PLASTIC SUPPORT. DWV & RAIN DRAINAGE) 2)REPAIR LEAK ON VENT IN 15103 3)PROVIDE SEPERATION OF HOT & COLD TUBING 4)PROVIDE APPROVED MATERIAL FOR TEMPERATURE & PRESSURE RELIEF DRAIN PIPING. THIS IS NOT A COMPLETE LIST
11/22/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*