Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM03399

Parcel: 13342001C

Inspection Status: Approved

Inspection History: ELECTRIC - TEMP POWER FOR TEST

Date Description Inspector Results Comments
08/19/2005 ELECTRIC - TEMP POWER FOR TEST Approved IVRS - Inspection :*
1) OK TEMP POWER FOR TEST