Inspection History: PLUMBING - FINAL
Permit Number - T03CM03373
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/26/2003 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*/1) PLBG FINAL IS OK. 2) OK FOR C. OF O. | |
08/25/2003 | PLUMBING - FINAL | Denied | 1) MUST PROVIDE BACKFLOW PREVENTERS FOR EACH HUMIDIFIER OR SHOW THAT UNITS DO NOT HAVE A SUBMERGED INLET. 2) INDIRECT WASTE THAT EXCEEDS 5' REQUIRES LINE TO BE TRAPED, IF INDIRECT WASTE EXCEEDS 15' THEN LINE MUST BE TRAPED AND VENTED. |