Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM03361
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/27/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
08/14/2003 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection 0000*/ 1) ITEMS #3, 5, 9, 14, 12, 13 INSPECTED AT INTERMEDIATES | |
08/12/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0145*/ 1) PLATE SPLICE AT INTERIOR GARAGE BEARING IS 3' 2) STRAP TOP PLATES WHERE NOT CABIN TIED 3) 3" EDGE NAILING AT SHEAR #9 4) NAIL GARAGE KINGS PER DETAIL 5) INSTALL GABLE BRACING PER DETAIL 6) FOLLOW NAILING PER 8, ABA 7) SHIM HEADERS AT FRONT PORCH 8) H2.5 5A TRUSS AT INTERIOR BEAM AND STRAP BEAM 9) PROVIDE ENGINEERED FIX AT TRUSS SB (6TH FROM FRONT AT POINT 14) 10) TRUSS 4C1 DOES NOT MATCH DETAIL 11) H2.5 TRUSS AD AT BOARD BEARING POINT 12) INSTALL BRACING AND STIFFNERS PER DETAIL AT TRUSS AD 13) PROVIDE ENGINEERING REVISION ON INTERNAL 2 X 6 TO 2 X 4 WALL 14) 16" ON CENTER MAXIMUM AT 2 X 6 INTERNAL WALL |