Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/11/2004 |
SHEET ROCK NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 02/09/2004 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0175*/ 1) GAPS AROUND ELECTRIC BOXES AND GAPS IN GYPSIUM PANELS WIDER THAN 1/4" NOT ALLOWED. FILL GAPS WITH HARD SETTING GYPSIUM COMPOUND, NOT DRYWALL COMPOUND. PER INSTALLTION STANDARD ?-A 216 SECTION 4.6.5.2 |
| 09/18/2003 |
SHEET ROCK NAILING |
|
Denied |
IVRS - Inspection 0999*/ 1) PROVIDE ENGINEERING APPROVAL FOR OVER LAYING 5/8" DRYWALL OVER 1/2" DRYWALL TO EQUAL REQUIREMENT FOR SHEAR |
| 09/16/2003 |
SHEET ROCK NAILING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) #4 SHEAR WALL IN GARAGE REQUIRES 5/8" DRYWALL. OK TO TAPE ALL BUT #4 SHEAR WALL |
| 09/16/2003 |
SHEET ROCK NAILING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |