Permit: T03CM03356

Parcel: 138242040

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
09/09/2003 FRAMING Approved IVRS - Inspection 0000*
09/08/2003 FRAMING Denied IVRS - Inspection 0999*
09/05/2003 FRAMING Denied IVRS - Inspection 0999*
09/04/2003 FRAMING Denied IVRS - Inspection 0950*/ 1) NO DWV WATER TEST. 2) INTERIOR BEARING WALL REQUIRES ABS AT 32" OR HILTI AT 8". 3) BLOCK AND NAIL ALL EDGES OF SHEAR WALL - DWV PENETRATING. 4) FIRE BLOCK MISSING K.T. 5) NAIL PROTECT WIRES WITHIN 1'9" OF STUD SURFACE. 6) RED HEAD A-BIS LOOSE. 7) GAS LINE MUST NOT TERMINATE IN WALL. / STOPPED INSPECTION, TOO MANY ITEMS.