Permit: T03CM03341

Parcel: 120072180

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
10/09/2003 ELECTRIC - RECONNECT Approved SENT TO TEP ON 1009AM OK TO RECONNECT UNITS 2 & 3
10/08/2003 ELECTRIC - RECONNECT Denied IVRS - Inspection 0245*/ NEED TO VERIFY LOAD CALC'S. FAX 791-3205 - ATTN: DAN SANTA CRUZ.
08/13/2003 ELECTRIC - RECONNECT Denied IVRS - Inspection 0245*/ NOTES: 1) UNITS MUST BE IDENTIFIED, ALSO SERVICE ENCLOSURE. 2) ELECTRICAL SERVICE EQUIP. AT UNITS NOT UP TO CODE. INDOOR TYPE BOXES, DICONNECTS EXPOSED TO WEATHER AND RAIN-DAMAGED. MUST BE REPLACED. ALSO FEEDER TO UNITS NOT PROPERLY SIZED AT RISERS. 3) UNITS MUST HAVE WORKING HEATING AND COOLING. 4) INSTALL SMOKE DETECTORS. WORK TO BE DONE BY LICENSED CONTRACTOR.