Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/15/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/28/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0950*/ 1) PROVIDE DETAIL FOR CONNECTING GARAGE SHEAR WALL #1 TO ROOF TRUSS SYSTEM 2) X BRACE TRUSSES AT 25 FEET ON CENTER 3) HEADERS MUST BEAR ON TRIMMERS 4) GARAGE SHEAR PANEL BY ENTRY NOT NAILED 5) NAIL PROTECT WIRES WITHIN 1 1/4" OF STUD SURFACE 6) MIXING OF ABS AND PVC IS NOT ALLOWED REMOVE ABS TUB DRAINS 7) NO DWV WATER TEST ON PLUMBING COMPLY WITH UPC 712.2 8) STOPPED INSPECTION TOO MANY ITEMS |