Permit: T03CM03327

Parcel: 140374240


Addresses:

7088 S DUNNOCK DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/15/2003 FRAMING Approved IVRS - Inspection 0000*
10/14/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) SEE #3 AND #2 FROM 10/09
10/10/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) SEE #1, 2 AND 3 FROM PREVIOUS INSPECTION
10/09/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) NAIL PROTECT ABS AT WATER HEATER PLATFORM 2) NAIL PROTECT ALL ELECTRICAL WITHIN 1 1/4" FROM EDGE OF STUD AND NO ROMEX TO TOUCH GUSSET PLATES 3) ROMEX TO EXHAUST FAN IN POWDER ROOM JUST DANGLING 4) NAIL PROTECT PLUMBING 2ND FLOOR 5) SECURE GAS LINE AT FAU 6) BLOCK MECHANICAL PLATFORM 7) NO TEST ON DWV'S SOUTH SIDE OF HOUSE 2ND FLOOR 8) SECURE WATER LINES AT MASTER SHOWER 9) FIRE BLOCK AT 2ND FLOOR BEDROOMS MISSING 10) WATER LINE BEHIND TUB TOUCHING GAS VENT, NEED 6" CLEARANCE
10/07/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) CANCELLED ON SITE BY SUPER 2) LATH NOT INSTALLED