Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
03/01/2004 BUILDING - FINAL Approved IVRS - Inspection 0000*
02/27/2004 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) STEPS-MAXIMUM 3/8' VARIANCE IN RISE 2) PROVIDE MEC AT WINDOWS/DOORS 3) PROVIDE INSULATION CERTIFICATE 4) INSTALL ALL OUTLET COVERS 5) GROUND SWITCHES 6) INSTALL LIGHT FIXTURES AT WALK THROUGHS 7) INSTALL DISHWASHER WITH DRAIN 8) SECURE FLEX AT A/C 9) INSTALL TRAP AT CONDENSATE 10) INSTALL SMOKE DETECTOR CIRCUIT 11) GROUND METAL BOXES 12) INSTALL OUTLETS PER PLAN 13) ID SERVICE PANEL FOR NEW CIRCUITS