Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/15/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 10/14/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) NOTHING DONE FROM LAST INSPECTION |
| 10/09/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) OVER SPANS STILL EXIST AT 2 X 6 BALLOON WALL 2) WIND BRACES MISSING NAILS 3) PATIO ROOF NOT COMPLETE 4) SHEAR NOT NAILED UPSTAIRS |
| 10/08/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999* / 1) MISSING KING STUD EACH SIDE ENTRY AT GARAGE 2) GABLE NOT NAILED TO TOP PLATE 12" ON CENTER 3) OVERSPANS AT SOUTH EAST WALL 2 X 6 4) OVERSPAN 2ND FLOOR-NAIL SHEAR NORTH WEST WALL 5) FIX OSB AT BACK PATIO 6) CHECK PERIMETER NAILING |