Permit: T03CM03306

Parcel: 140374090


Addresses:

6165 E STONECHAT DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/29/2003 FRAMING Approved IVRS - Inspection 0000*
10/28/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) LINE SET FOR FAU NOT COMPLETE 2) MECHANICAL NOT BLOCKED
10/27/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) MECHANICAL NOT BLOCKED 2) MOVE ROMEX AWAY FROM GUSSETT PLATES 3) PLUMBERS TAPE NOT ALLOWED TO SUPPORT ABS 5) NAIL PROTECT PLUMBING WITHIN 1 1/2 FROM EDGE OF STUD 6) FIX FIRE BLOCK AT STAIR PLATFORM 7) NO TEST ON DWV'S UPSTAIRS 8) STOPPED INSPECTION TOO MANY ITEMS. RECALL WHEN READY, WILL REINSPECT ENTIRE HOUSE