Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/29/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/28/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) LINE SET FOR FAU NOT COMPLETE 2) MECHANICAL NOT BLOCKED |
| 10/27/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) MECHANICAL NOT BLOCKED 2) MOVE ROMEX AWAY FROM GUSSETT PLATES 3) PLUMBERS TAPE NOT ALLOWED TO SUPPORT ABS 5) NAIL PROTECT PLUMBING WITHIN 1 1/2 FROM EDGE OF STUD 6) FIX FIRE BLOCK AT STAIR PLATFORM 7) NO TEST ON DWV'S UPSTAIRS 8) STOPPED INSPECTION TOO MANY ITEMS. RECALL WHEN READY, WILL REINSPECT ENTIRE HOUSE |