Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 10/08/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 10/07/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) FIRE BLOCK WATER HEATER PLATFORM 2) REPLACE ROMEX AT POWDER ROOM 3) FIRE BLOCK PLATFORM 4) NO TEST ON DWV'S UPSTAIRS 5) SECURE GAS LINE UPSTAIRS BEHIND UNIT 6) BLOCK MECHANICAL PLATFORM 7) FIX FIRE BLOCK UPSTAIRS BEDROOM TO RIGHT 8) WATER LINE BEHIND TUB NEEDS TO BE 6" AWAY FROM WATER HEATER FLUE 9) WATER LINES OK 10) CLIP STRINGER |
| 10/06/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) CANCELLED ON SITE BY SUPER |
| 10/02/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |