Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 09/25/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 09/24/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) SEE PREVIOUS INSPECTION |
| 09/23/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) REPLACE GREEN PLATES AT GARAGE POP-OUT AND INSTALL WASHER AND NUT 2) SHEAR NOT NAILED AT FRONT PATIO ABOVE DOOR 3) HANGERS FRONT PATIO MISSING NAILS |
| 09/18/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) SEE LAST INSPECTION |
| 09/17/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) AT GARAGE OPENING MISSING PLATES AT EACH SIDE 2) GABLE END TRUSSES NOT STRAPED TO TOP PLATES 3) FRONT PORCH MISSING H2.5'S 4) MISSING STHD8 AT FRONT WALL 5) MISS PA TO SHEAR WALL REAR, NEXT TO SLIDER 6) ATTACH SHEAR TO TRUSS 7/SD3 A35 FLAT 48" ON CENTER 7) MISSING ROOF NAILING-SEE BLACK MARKS 8) LEAVE TRUSS DRAWINGS ON SITE AT ROOF NAIL |