Permit: T03CM03260

Parcel: 13811082A


Addresses:

6348 S NOGALES HY

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
05/10/2004 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*/ 1) SOIL WTR TEST IS OK. 2) OVERHEAD WTR DISTRIBUTION IS OK. 3) GAS PRESSURE TEST IS OK.
05/05/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ DOOR WAS LOCKED.
05/04/2004 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) MUST VERIFY MARKINGS ON COPPER 2) MUST PROVIDE WATER TEST ON NEW WASTE AND VENT SYSTEM 3) MUST PROVIDE CLEANOUT FOR FLOOR SINK 4) CANNOT RUN A 2" TRAP ARM FOR WET VENT ON A 2" RISER BARREL MUST BE 1 PIPE SIZE LARGER 5) MUST USE STEEL UNISTRUT CLAMP FOR GAS LINE
04/30/2004 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection :*