Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/21/2003 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 11/14/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) THERE IS A DOUBLE TAPED GROUND, CONSISTING OF A #14 AND #12 WIRE. DOUBLE TAPS MUST BE SAME SIZE 2) IF THERE IS PLASTIC WATER PIPING IN THE HOUSE, IT MUST BE NOTED ON THE PANEL DEADFRONT 3) THE DRYER VENT FLAPPER IS STUCK CLOSED 4) UNKINK DRYER VENT FLEX DUCT 5) LAUNDRY ROOM VENT IS MISISNG IT'S FLAPPER 6) CORRECT WASHOUT DRAINAGE PROBLEM AT NORTHEAST CORNER OF HOUSE, UNDER THE EAST PROPERTY WALL 7) TAPE HOT WATER HEATER FLUE JOINTS 8) EXTEND FLUE PIPE ABOVE PARAPET 9) REMOVE CONDENSATE LINE FROM VENT PIPE 10) NEED INSULATION AND STUCCO CERTS |