Permit: T03CM03215

Parcel: 117072290


Addresses:

326 E 17TH ST


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM03215

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
07/26/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
07/19/2004 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :NAIL RIDGE DECKING TO RIDGE BOARD & NAIL ALL DECKING AT HIP AND VALLEY RAFTERS
NAILING IS 6" O.C. AT ENDS & JOISTES 12" O.C. IN THE FIELD
EAST WALL NO DETAIL FOR SHORT 2X6'S UNDER RAFTERS TO TOP PLATE, INSTALL A RIPPER OF 1/2 PLYWOOD TO INSIDE OF THOSE SHORT 2X6'S
FINISH ROOF DECK
MAKE SURE ALL COLLAR TIES = CEILING JOISTS ARE SECURED AT EA END