Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - SEWER HCS CONNECT
Permit Number - T03CM03192
Inspection Description - PLUMBING - SEWER HCS CONNECT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/30/2004 | PLUMBING - SEWER HCS CONNECT | Approved | IVRS - Inspection :* | |
09/13/2004 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :* 03055 STILL ?? VERIFICATION OF GRADE ON SEWER 03005 PIPE WRAPS & TRAP ?? OK SILL NEED REVISED DRAWINGS & LETTER FROM ENGINEER OK ABS INSTEAD OF SPEC. NO HUB CAST IRON |
|
04/23/2004 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection :*/ MH #2 TO MH #3 6" SDR 35 AIR TEST OK. MH #3 VACUUM TEST OK. MH #4 VACUUM TEST OK. NEED STAMPED VERIFICATION OF GRADE ON SEWER FROM MH #2 TO MH #4. | |
04/14/2004 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection 0000*/ PLEASE CALL ME AND SCHEDULE A VACUUM TEST SEE NOTES FROM 4/12/04 | |
04/12/2004 | PLUMBING - SEWER HCS CONNECT | Partial Approval | IVRS - Inspection 0000*/ WTR TEST FROM MH.3, 6" SDR 35 THRU MH 4 AND THRU 4" SDR 35 BLD STUB OK INCLUDING 4" BLD STUB TO PARCEL #3. MH 2 TO MH 3 WILL REQUIRE AIR TEST. VACUUM TEST WILL BE REQUIRED ON ALL MH. WILL NEED STAMPED VERIFICATION OF GRADE. RECEIVED ONE PIMA CO. VERIFICATION OF GENERAL PERMIT CONFORMANCE. ONE JOINT SHARED USE AGREEMENT FOR SEWER PIPING. | |
04/09/2004 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection 0000*/ SEE NOTES ABOVE AND HAVE SOMEONE PRESENT TO PROVIDE INFORMATION AT TIME OF INSP. | |
04/06/2004 | PLUMBING - SEWER HCS CONNECT | Not ready for Inspection | IVRS - Inspection 0000*/1) PROVIDE CITY APPROVED DRAWINGS ON SITE. 2) PROVIDE JOINT MAINTENANCE AGREEMENT FOR SEWER BY ALL OWNERS. 3) PROVIDE CERTIFICATION OF COMPLIANCE FOR PIMA CO. FOR SEWER. 4) PROVIDE VERIFICATION OF GRADE FOR SEWER |