Permit: T03CM03192

Parcel: 140420460


Addresses:

6608 S TUCSON BL


Inspection Status: Approved

Inspection History: PLUMBING - ABOVE CEILING

Permit Number - T03CM03192

Inspection Description - PLUMBING - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
11/30/2004 PLUMBING - ABOVE CEILING Approved IVRS - Inspection :*/CORRECTION MADE, REVISED CITY APP. PLAN ON SITE
11/24/2004 PLUMBING - ABOVE CEILING Partial Approval IVRS - Inspection :*/H2O PIPING WATER TEST OK. CLOSET FLANGES OK. WASTE & VENT THRU ROOF WATER TEST OK. 15 PSI AIR TEST ON GAS PIPING PER PLAN OK. 1)PROVIDE DIELECTRIC ON H2O SUPPLY 2)PROVIDE HANGERS & SUPPORTS AT 4' INTERVALS ON PLASTIC PIPING ON HORIZONTAL 3)PROVIDE ADDITIONAL HANGERS FOR 1/2 HAR? PIPING