Inspection Status: Approved
Inspection History: PLUMBING - ABOVE CEILING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/30/2004 |
PLUMBING - ABOVE CEILING |
|
Approved |
IVRS - Inspection :*/CORRECTION MADE, REVISED CITY APP. PLAN ON SITE |
| 11/24/2004 |
PLUMBING - ABOVE CEILING |
|
Partial Approval |
IVRS - Inspection :*/H2O PIPING WATER TEST OK. CLOSET FLANGES OK. WASTE & VENT THRU ROOF WATER TEST OK. 15 PSI AIR TEST ON GAS PIPING PER PLAN OK. 1)PROVIDE DIELECTRIC ON H2O SUPPLY 2)PROVIDE HANGERS & SUPPORTS AT 4' INTERVALS ON PLASTIC PIPING ON HORIZONTAL 3)PROVIDE ADDITIONAL HANGERS FOR 1/2 HAR? PIPING |