Date Description Inspector Results Comments
11/30/2004 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
09/13/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
09/02/2004 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
09/01/2004 PLUMBING - ROUGH, SOIL Partial Approval WATER TEST UNDERGROUND ONLY OK COVER AT OWN RISK AND PROVIDE REVISED CITY APPROVED PLANS OF CHANGES FROM REP LINES ON SITE
SEWER HCS CONNECTION OK
08/31/2004 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection :SHALL PROVIDE L-SWEEP ON VENT FOR FLOOR DRAIN THAT IS VENTED HORIZONTAL BELOW FLOOD RIM LEVEL
SHALL PROVIDE VENT FOR GREASE TRAP
SHALL PROVIDE 4" C.O. WOMEN'S BATHROOM