Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T03CM03183
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/05/2003 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
| 08/04/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0145*/ 1) NAIL TRIPPLE POSTS 2) INSTALL AB'S AT PORCH COLUMN | |
| 08/01/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0145*/ 1) SEE PREVIOUS INSPECTIONS 2) DETAIL 13/DT1, 6/DT1, OVER NOTCHING, 12/DT1, OVERSPAN, ETC.. | |
| 07/29/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0145*/ 1) SEE PREVIOUS INSPECTION | |
| 07/28/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) ON ROOF STAPLES NEED TO BE FLUSHED WITH SHEATHING 2) CHECK FOR OVER SPAN FRAMING EXTERIOR WALLS 3) WIND BRACE SOUTH WEST CORNER NOT EXTENDING TO DOUBLE TOP PLATE 4) CLIP AND NAIL ALL DOUBLE STUDS AT SOUTH WEST CORNER 5) REPLACE WIND BRACE SOUTH EAST CORNER 6) TRIPPLE KING STUD AT GRAGE NOT NAILER 7) NEXT FAILURE WILL RESULT IN A REFEE | |
| 07/26/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0950*/ 1) NOT COMPLETE ENOUGH TO INSPECT | |
| 07/23/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) NOT COMPLETE ENOUGH TO INSPECT | |
| 07/22/2003 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0145*/ 1) INSTALL ALL CLIPS PER DETAIL AND STRAPS 2) DOUBLE STUD OVERNOTCHED 3) COMPLETE SHEAR NAILING 4) COMPLETE ALL H.D. NAILING 5) TWO NAIL BOTH ENDS OF RCWB 6) STRAP OVER NOTCHED TOP PLATE 7) STRAP ALL SOLE PLATES AT PLUMBING OVERNOTCHES 8) TRIPLE KING AND MST 48 AT GARAGE HEADER | |
| 07/21/2003 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000* |