Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T03CM03183

Parcel: 116035660


Addresses:

1457 N OLD RANCH RD


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T03CM03183

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
08/05/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/04/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0145*/ 1) NAIL TRIPPLE POSTS 2) INSTALL AB'S AT PORCH COLUMN
08/01/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0145*/ 1) SEE PREVIOUS INSPECTIONS 2) DETAIL 13/DT1, 6/DT1, OVER NOTCHING, 12/DT1, OVERSPAN, ETC..
07/29/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0145*/ 1) SEE PREVIOUS INSPECTION
07/28/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ON ROOF STAPLES NEED TO BE FLUSHED WITH SHEATHING 2) CHECK FOR OVER SPAN FRAMING EXTERIOR WALLS 3) WIND BRACE SOUTH WEST CORNER NOT EXTENDING TO DOUBLE TOP PLATE 4) CLIP AND NAIL ALL DOUBLE STUDS AT SOUTH WEST CORNER 5) REPLACE WIND BRACE SOUTH EAST CORNER 6) TRIPPLE KING STUD AT GRAGE NOT NAILER 7) NEXT FAILURE WILL RESULT IN A REFEE
07/26/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0950*/ 1) NOT COMPLETE ENOUGH TO INSPECT
07/23/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*/ 1) NOT COMPLETE ENOUGH TO INSPECT
07/22/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0145*/ 1) INSTALL ALL CLIPS PER DETAIL AND STRAPS 2) DOUBLE STUD OVERNOTCHED 3) COMPLETE SHEAR NAILING 4) COMPLETE ALL H.D. NAILING 5) TWO NAIL BOTH ENDS OF RCWB 6) STRAP OVER NOTCHED TOP PLATE 7) STRAP ALL SOLE PLATES AT PLUMBING OVERNOTCHES 8) TRIPLE KING AND MST 48 AT GARAGE HEADER
07/21/2003 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*