Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/24/2004 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/19/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) NO ATTIC ACCESS 2) SHIM HEADER GAPS 3) PORCHES NOT COMPLETE AT WET BAR TOP PLATES 4) MAKE UP ALL CANS 5) GROUND EXTERIOR METAL BOXES 6) GROUND ALL INTERIOR METAL BOXES 7) NAIL PROTECT COPPER PLUMBING 8) NAIL PROTECT DRAIN NW BATH 9) NAIL PROTECT COPPER NW SHOWER CORNER 10) NO WATER TEST BATH PLUMBING 11) COMPLETE FIREPLACE FLU 12) STOPPED INSPECTION |
|
| 11/14/2004 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) HEADER SCHEDULE SHOWS H-3 CLIPS FROM TRIMMERS TO HEADER 2) WEST GARAGE GIRDER TRUSS POST SHOULD BE 3-2 X 6'S PER PLAN 3) NAIL OFF BOTTOM OF WEST VALLEY ON GARAGE AND FLUSH NAILS ON N.E. GARAGE ROOF 4) NAIL OFF PLY THROUGH FASCIA ON NORTH SIDE OF NORTH ADDITION 5) 1 ROW NAILING MISSED AT S.E. CORNER OF N. ADDITION 6) NAIL OFF MIDDLE STUD-NORTH OF WEST GARAGE MAN DOOR 7) STRAP GARAGE GABLE TRUSS DOWN TO KINGS 8) NO ATTIC ACCESS PRESENT PER PLAN 9) SHIM TRIMMER/HEADER GAPS 10) NORTH ADDITION NOT INSPECTED-PLEASE RECALL 11) STOPPED INSPECTION BEFORE NORTH ADDITION 12) PLEASE RECALL |