Permit: T03CM03181

Parcel: 127070810


Addresses:

5222 E 5TH ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/24/2004 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/19/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NO ATTIC ACCESS
2) SHIM HEADER GAPS
3) PORCHES NOT COMPLETE AT WET BAR TOP PLATES
4) MAKE UP ALL CANS
5) GROUND EXTERIOR METAL BOXES
6) GROUND ALL INTERIOR METAL BOXES
7) NAIL PROTECT COPPER PLUMBING
8) NAIL PROTECT DRAIN NW BATH
9) NAIL PROTECT COPPER NW SHOWER CORNER
10) NO WATER TEST BATH PLUMBING
11) COMPLETE FIREPLACE FLU
12) STOPPED INSPECTION
11/14/2004 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) HEADER SCHEDULE SHOWS H-3 CLIPS FROM TRIMMERS TO HEADER
2) WEST GARAGE GIRDER TRUSS POST SHOULD BE 3-2 X 6'S PER PLAN
3) NAIL OFF BOTTOM OF WEST VALLEY ON GARAGE AND FLUSH NAILS ON N.E. GARAGE ROOF
4) NAIL OFF PLY THROUGH FASCIA ON NORTH SIDE OF NORTH ADDITION
5) 1 ROW NAILING MISSED AT S.E. CORNER OF N. ADDITION
6) NAIL OFF MIDDLE STUD-NORTH OF WEST GARAGE MAN DOOR
7) STRAP GARAGE GABLE TRUSS DOWN TO KINGS
8) NO ATTIC ACCESS PRESENT PER PLAN
9) SHIM TRIMMER/HEADER GAPS
10) NORTH ADDITION NOT INSPECTED-PLEASE RECALL
11) STOPPED INSPECTION BEFORE NORTH ADDITION
12) PLEASE RECALL