Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T03CM03155

Parcel: 116213990


Addresses:

536 S STEPHANIE LP

Inspection Status: Approved

Inspection History: U VALUE FOR WINDOW

Date Description Inspector Results Comments
08/13/2004 U VALUE FOR WINDOW Approved IVRS - Inspection :*
08/11/2004 U VALUE FOR WINDOW Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) NO LABEL ON WINDOW 2) UNCOVER PLUMBING YARDWATER AND HCS CONNECTIONS 3) SECURE FURNACE A/C FLUE PIPE SECURELY 5) INSTALL VENT A/C CONDENSATE 6) SCREW H20 HEATER FLUE PIE JOINTS TOGETHER 7) MAINTAIN 6" CLEARANCE TO COMBUSTIBLES OR SWITCH TO TYPE B VENT 8) NEED ALL CERTS 9) NEED COPY OF ? EASEMENT ON JOB. DIRECTLY WEST FOR ACCESS TO UTILITIES 10) STOPPED INSPECTION 11) NEED LADDER TO INSPECT ON ROOF