Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/24/2006 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/05/2005 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PENDING MECHANICAL APPROVAL 2) PENDING INSTALLATION OF REFRIDGERANT LINES 3) PROVIDE 1" AT WATER HEATER FLUE FROM COMBUSTIBLES 4) OK TO INSULATE AND SHEETROCK |
|
| 10/10/2005 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SCREWS MAY NOT BE USED AT H2.5 HANGERS 2) BLOCK TUB WALLS 3) GROUND ALL METAL BOXES 4) PIGTAIL AND GROUND ALL SWITCH BOXES 5) INSTALL TUB 6) GROUT TUB SHOE 7) NO WATER TEST DWV SYSTEM-COPPER OK 8) NOT CONNECTED TO METER ONLY 9) PROVIDE GAS AND COPPER BONDS |
|
| 02/24/2005 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |