Inspection History Details
Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T03CM03070
Inspection Description - ROOF NAILING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2006 | ROOF NAILING | Approved | IVRS - Inspection :* | |
| 05/26/2006 | ROOF NAILING | Cancelled | CANCELLED PER STEVE #940-3651 | |
| 05/26/2006 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection :* 1) CANCELLED PER OFFICE |
|
| 04/14/2006 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection :* | |
| 12/07/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SHEATHING EXCESSIVELY WEATHERED-REPLACE OR HAVE ENGINEER APPROVAL 2) COMPLETE ALL WORK PRIOR TO INSPECTION |
|
| 11/21/2005 | ROOF NAILING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED APPROVED TRUSS DRAWINGS AND APPROVED PLANS 2) CROSS BRACE 1ST AND 3RD TRUSS (X-CONFIGURATION) 3) JOINTS IN HORIZONTAL WOOD PLATES TO OCCUR OVER STUDS 4) FILL IN GAPS UNDER HEADERS AT BEARING TRIMMER STUDS 5) NAIL ALL EXTERIOR OSB SHEATHING AT 6"/12" PATTERN 6) BOLTS COUNTER SINK INTO BOTTOM WOULD PLATE EXCESSIVELY 7) INCORRECT HANGERS USED ON I-JOISTS 8) NEED POSITIVE CONNECTION 2 X PLATE TO GLB 9) STRAP GLB AND ALL HEADERS AT BEARING POINTS 10) STAIR RISE AND RUN NOT TO CODE 11) INSTALL BOLTS ALL METAL CONNECTORS BEAMS 12) NEED LADDER AT INSPECT ROOF, UNABLE TO LOCATE APPROVED PLANS 13) STOPPED INSPECTION |