Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM03045
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/08/2003 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000* | |
07/06/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999* 1) HORIZONTAL VENTING BELOW FLOOD LEVEL NOT ALLOWED. 2) CONNECTION BETWEEN COPPER AND ABS TO BE APPROVED TRANSITON FITTING. 3) CONNECTION BETWEEN ABS x ABS TO BE SOLVENT WELD COUPLING 4) OVER NOCHED STUD AT SHWR P-TRAPL 5) MAY NOT STUB OUT 2" AT LAVATORIES 6) CLOSET FLANGES NOT SECURED 7) HORIZONTAL ABS TO BE SUPORTED |