Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T03CM03025
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/20/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
08/18/2003 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) 8 FEET SHEAR BLOCK MISSING AT SHOWER 2) NAIL PROTECT PLUMBING WITHIN 1 1/4" OF STUD SURFACE 3) RELOCATE WIRES AT POT SHELF OR PROTECT 4) RED HEAD ANCHOR BOLTS LOOSE 5) GARAGE MISSING TRUSS BRACING 6) PROVIDE TRUSS DRAWINGS 7) PLATES REQUIRE ANCHOR BOLTS WITHIN 12" OF ENDS AND SPLICES 8) PROVIDE SHEAR TRANSFER |