Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/18/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 08/15/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) ITEM 1 OF 8/12/03 INSPECTION NOT COMPLIED WITH 2) ITEM 2 OF 8/12/03 INSPECTION NOT COMPLIED WITH |
| 08/12/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) GARAGE GABLE TRUSS NOT CLIPPED AT ENDS 2) ENTRY TRUSS NOT CLIPPED 3) NAIL PROTECT ALL PLUMBING CUTS AT SILL PLATE 4) PORCH LEDGER NOT CLIPPED PER 9/DT1 5) STOPPED INSPECTION-TOO MANY ITEMS 6) ROOF NOT CHECKED STILL NAILING |
| 08/11/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0950*/ 1) NAIL PROTECT PLUMBING 2) SHEAR NOT NAILED 3) STOPPED INSPECTION |