Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/18/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 08/15/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) NON OVERLAPPING DOUBLE TOP PLATES NOT STRAPPED 2) INTERIOR NON BEARING WALLS REQUIRE 1/2" CLEARANCE TO SCISSOR TRUSS BOTTOM CHORD 3) ONE ROOF PANEL NOT NAILED AT RIDGE 20 FEET FROM REAR |
| 08/14/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0950*/ 1) STRAP NON OVER LAPPING DOUBLE TOP PLATES CABIN TIES NOT IN 2) BLOCK TRUSSES SUPPORTING ENTRY 3) CORNER STUDS NOT CLIPPED 4) CLIP KING STUDS 5) R5 P4 CLIPS NOT NAILED 6) STOPPED INSPECTION, TOO MANY ITEMS |
| 08/13/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0950*/ 1) TWO FRONT TRUSSES NOT CLIPPED 2) STRAP HEADERS TO KING STUDS TO PLATES 3) STRAP NON CABIN TIE CORNERS 4) STOPPED INSPECTION-TOO MANY ITEMS |