Permit: T03CM03009

Parcel: 126111310


Addresses:

4407 E WHITMAN ST

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESS TEST FNL

Date Description Inspector Results Comments
07/21/2003 PLUMBING - GAS PRESS TEST FNL Approved IVRS - Inspection 0000*
07/18/2003 PLUMBING - GAS PRESS TEST FNL Denied IVRS - Inspection 0999*/ 1) EVEN THOUGH THIS IS FOR TEMPORARY USE WHILE UNDER CONSTRUCTION YOU WILL NEED TO A) SECURE GAS PIPING AT WATER HEATER LOCATION B) INSTALL AND EXTEND WATER HEATER FLUE PIPE ABOVE ROOF LINE C) REMOVE "T" FITTING FROM LINE AT HOUSE 2) MINIMUM 10 POUND PRESSURE TEST REQUIRED 3) ALSO EXTEND PTR LINE WATER HEATER TO WITHIN 6" OF GROUND