Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T03CM03006
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/21/2003 | PLUMBING - INTERMEDIATE | Approved | ||
07/29/2003 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK 2) OVERHEAD WATER DISTRIBUTION IS OK 3) P.O.C. OF NEW BLDG DRAIN TO EXISTING BLDG DRAIN IS OK 4) OK FOR DRYWALL | |
07/25/2003 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection 0999*/ 1) 2" WASTE HAS BACK PITCH. 2) MUST USE L SWEEP FOR DRAINAGE FROM VERTICAL TO HORIZONTAL. 3) MUST VERIFY TEST ALL THE WAY TO P.O.C. OF VENT. 4) MUST PROVIDE RISER CLAMP. |