Permit: T03CM03006

Parcel: 128100800

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
08/21/2003 PLUMBING - INTERMEDIATE Approved
07/29/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*/ 1) SOIL WATER TEST IS OK 2) OVERHEAD WATER DISTRIBUTION IS OK 3) P.O.C. OF NEW BLDG DRAIN TO EXISTING BLDG DRAIN IS OK 4) OK FOR DRYWALL
07/25/2003 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*/ 1) 2" WASTE HAS BACK PITCH. 2) MUST USE L SWEEP FOR DRAINAGE FROM VERTICAL TO HORIZONTAL. 3) MUST VERIFY TEST ALL THE WAY TO P.O.C. OF VENT. 4) MUST PROVIDE RISER CLAMP.