Permit: T03CM02978

Parcel: 125042490


Addresses:

2121 E HAWTHORNE ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/26/2004 FRAMING Approved IVRS - Inspection 0000*
02/25/2004 FRAMING Not ready for Inspection IVRS - Inspection 0000*
02/24/2004 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) MADE UP GROUND MUST BE SECURED WITH MECHANICAL FASTENERS ( ? OR WIRE NUTS) 2) COPPER PLUMBING MSUT BE ELECTRICALLY BONDED 3) RANGE BOX REQURES ROMEX CLAMP AND BONDING 4) ISOLATE COPPER PLUMBING FROM GALVANIZED FRAME BY WATER HEATER 2) MAD
02/23/2004 FRAMING Denied IVRS - Inspection 0999*/ 1) MAKE-UP GROUNDS IN ELECTRIC BOXES 2) IMPROPER VENT CONNECTION AT SHOWER 3) WATER TEST REQUIRED ON DWV 4) WATER LINES OK 5) FRAMING WITHELD FOR ELECTRIC 6) OK TO INSULATE NON PLUMBING WALLS
02/19/2004 FRAMING Cancelled IVRS - Ri canceled