Permit: T03CM02969

Parcel: 108163300

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
08/14/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
08/13/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ANY PIECE OF ROOF OSB THAT DOES NOT SPAN 2 TRUSS BAYS (3 TRUSSES) MUST BE BLOCKED AND NAILED ON 4 SIDES 2) ANY PIECE OF ROOF OSB THAT DOES NOT HAVE 24" OF WIDTH MUST HAVE H CLIPS 3) ALL ROOF OSB MUST HAVE 1/8" BETWEEN ALL PIECES 4) H2.5 PATIO WALK DECK LEDGER 5) STRAP ALL EXTERIOR TOP PLATES THAT ARE NOT CABIN TIED