Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 08/14/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 08/13/2003 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) ANY PIECE OF ROOF OSB THAT DOES NOT SPAN 2 TRUSS BAYS (3 TRUSSES) MUST BE BLOCKED AND NAILED ON 4 SIDES 2) ANY PIECE OF ROOF OSB THAT DOES NOT HAVE 24" OF WIDTH MUST HAVE H CLIPS 3) ALL ROOF OSB MUST HAVE 1/8" BETWEEN ALL PIECES 4) H2.5 PATIO WALK DECK LEDGER 5) STRAP ALL EXTERIOR TOP PLATES THAT ARE NOT CABIN TIED |