Permit: T03CM02963

Parcel: 140374140


Addresses:

7011 S GULL LN

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/06/2003 FRAMING Approved IVRS - Inspection 0000*
10/02/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) LATHERS STILL WORKING ON HOUSE 2) NO AIR TEST ON GAS LINE DEFECTIVE GUAGE 3) NO TEST ON DWV'S OR WATER LINES 4) DOUBLE TOP PLATE IN GARAGE OVER BOARED 5) CLIPS MISSING AT GARAGE WALL TOP PLATE TO BOTTOM CHORD 6) NAIL SHEATHING AT BEAM ABOVE ENTRY CLOSER 7) SECURE WATER LINES 2ND FLOOR BETWEEN BEDROOMS 8) NAIL PROTECT ALL ELECTRIC WITHIN 1 1/4" FROM EDGE OF STUD 9) SECURE CONDENSATE LINE