Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T03CM02961

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
10/10/2003 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*/ 1) WASTE AND VENT SYSTEM IS OK. 2) OVERHEAD WATER DISTRIBUTION IS OK. 3) GAS PRESSURE TEST IS OK.
10/06/2003 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*/ MUST HAVE HUB ON DUCTILE IRON FACING THE HOUSE.
09/29/2003 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*/1) MUST PROVIDE WATER TEST ON WASTE AND VENT SYSTEM ALL THE WAY TO TOP OF VENT AND THRU ROOF. 2) I DO NOT ACCEPT COPPER BACKING WITH TIE WIRE FOR TUB DIVERTERS. 3) CAN NOT HAVE A 2" TRAP ARM FOR LAVATORYS. MAX TRAP ARM FOR THIS FIXTURE IS 1-1/2". 4) GAS PRESSURE TEST IS OK.